Hubei Haite New Material Co., Ltd. | Water Decoloring Agent, PAC, PAM
Quality control laboratory pH and jar test for water treatment chemicals

Decolorizing Agent Dosage Calculation



Technical Calculation · Dosage · ppm Reference

Decolorizing Agent Dosage Calculation

A simple dosage calculation reference for water decoloring agent, PAC and PAM jar tests in wastewater treatment.

01Volume
02Drops
03ppm

Basic Formula

This formula is used as a reference for jar test dosage calculation. Plant-scale dosage should be confirmed by test and operation conditions.

Dosage (ppm) = [(Drops ÷ 20) × Concentration (%) ÷ Wastewater Volume (L)] × 10,000

In the original test reference, 20 drops are considered approximately 1 ml. Please treat this as a laboratory reference only.

Example Calculation

For 200 ml wastewater sample, if 10 drops of 2% water decoloring agent solution are added:

Item Value
Wastewater sample 200 ml = 0.2 L
Chemical solution 2% diluted water decoloring agent
Added volume 10 drops = 0.5 ml reference
Calculated dosage Approx. 50 ppm reference

Calculation Notes

Dosage calculation is only one part of testing. Final selection must compare actual treatment results.

Do Not Judge by Dosage Alone

Compare color, clarity, floc strength, settling speed and sludge amount.

pH Matters

pH can affect decolorization and coagulation performance. Check pH before dosing.

Sequence Matters

The dosing order of decoloring agent, PAC and PAM may affect final result.

Suggested Testing Table

Use multiple dosage points to avoid missing the optimal range.

Test Cup Decolorizing Agent PAC PAM Observation
Blank 0 0 0 Original color and settling
A Low Fixed Fixed Check color reduction
B Medium Fixed Fixed Compare clarity and floc
C High Fixed Fixed Check overdosing possibility

Need Dosage Help?

Send your test volume, dilution concentration, drops/ml added and treatment result. We can help review the calculation direction.


Official Website Images Integrated

Jar-Test and Quality-Control Visual References

These official images help visitors understand how Hubei Haite evaluates color removal, floc formation, settling performance and dosage matching before recommending a chemical program.

Jar-test sample and color comparison
Jar-test sample and color comparisonOfficial Hubei Haite website material
Official product test visual
Official product test visualOfficial Hubei Haite website material
Decoloring agent performance visual
Decoloring agent performance visualOfficial Hubei Haite website material
Wastewater treatment sample visual
Wastewater treatment sample visualOfficial Hubei Haite website material
ColorCheck visible color removal
FlocObserve floc size and settling
CODEvaluate combined treatment needs
DosageRecord ppm for scale-up

Updated website visuals

Laboratory testing and quality-control visuals

These images are matched to laboratory evaluation, pH checking, jar test and batch quality control content.

Quality control laboratory pH and jar test for water treatment chemicals
Quality control laboratorypH and sample testing
Jar test process showing textile wastewater color removal stages
Jar-test sequenceColor removal stages
Engineer testing water treatment chemicals in factory laboratory
Factory lab engineerTechnical support and QC